Learn moreFlexible stainless liners (316Ti for solid fuel, 304 for gas) for chimneys with offsets, bends, or unusual cross-sections where rigid liners can't pass. UL-1777 listed, lifetime warranty.
Prices shown are starting estimates and may change with the condition, access, and scope we find on site. Only a written quote from an on-site visit is a price we commit to.
This page is about a material choice, not a separate service: when a flue needs a liner, should it be the flexible corrugated stainless tube or a rigid one? Flexible wins exactly when the geometry defeats rigid pipe — a chimney with an offset or 'dogleg,' an elbow at the smoke chamber, an out-of-round or shouldered clay tile, or a tight throat a stiff length can't be fed through. The corrugation lets the liner bend around the bends and compress through the pinch points while still sealing as one continuous channel. How this differs from the general relining page: relining is the decision to replace a failed liner and may end in flexible, rigid, or cast-in-place; this page is specifically the flexible option, chosen on geometry and appliance, whether the flue is being relined or lined for the first time.
Choosing flexible is a measurement before it is a purchase. We camera-scope the flue and map every offset, elbow, and dimensional pinch, then decide whether flexible is required (rigid won't pass) or simply preferred. Where rigid would pass a straight, accessible flue, we tell you so — rigid liner has smoother walls and marginally better draft, so we don't sell flexible by default. Where the throat is tight, we run an oval-profile flexible liner of equal cross-sectional area so it passes where a round one won't. The alloy still tracks the fuel — 316Ti stainless for wood, oil, coal, or high-sulfur fuels, 304 where the fuel allows — because a flexible liner of the wrong alloy corrodes exactly as fast as any other.
The flexible liner is also the natural match for appliance venting, which is much of why this type exists. Dropping a liner from a gas or wood fireplace insert down to the appliance collar almost always means negotiating the offset between the flue and the insert's outlet, and flexible makes that positive, full-length connection where rigid would bind — never a non-connected 'slammer.' Venting a stove or a high-efficiency appliance through an existing masonry chimney has the same geometry problem, and the flexible tube solves it. Because corrugation slightly slows draft and runs cooler, we add a liner-insulation wrap on solid-fuel and many appliance installs — it holds flue temperature up for draft, keeps creosote down, and maintains clearance to combustibles where the run passes near framing.
Installation is geometry-aware from top to bottom: we feed the liner from above, ease it through each offset rather than forcing it, insulate or pour-mix as required, and lock positive top-plate and appliance-collar connectors so the corrugated run is gas-tight end to end. Then we prove it — a smoke or draft check confirms the sealed path, and we document the UL-1777 listing for your records and any warranty, which on flexible liners is typically conditional on annual sweeping. How this differs from flue installation: that page often builds a brand-new, straight flue where a smooth clay or rigid run is the better first-time choice; flexible is the retrofit answer for an existing crooked flue rigid can't follow. The same scoping, alloy-matching, and insulation discipline governs every flexible-liner install across our national network.
At Prime Chimney Experts, a flexible chimney liner installation is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the flexible chimney liner installation is built on.
Chimney inspectionA flexible chimney liner installation isn't a matter of opinion — it's held to published national standards. Prime Chimney builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
The flexible stainless liner is a UL-1777 listed lining system, certified for the application and documented for inspection — its listing only holds when installed per the manufacturer's instructions.
Alloy is matched to the fuel — 316Ti stainless for wood, oil, coal, or high-sulfur fuels, 304 where the fuel allows — because the flexible material corrodes early in the wrong alloy and voids the warranty.
The flexible liner is run through the flue's offsets and elbows within the manufacturer's listed bend radius — eased, not forced — so the corrugated wall is not kinked or torn where a rigid liner simply could not pass.
On solid-fuel and many appliance installs the flexible liner is insulated to hold flue temperature for draft and to maintain clearance to combustibles where the run passes near framing — 2 in interior masonry / 1 in exterior per the IRC.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Prime Chimney verifies them with your local authority having jurisdiction on every job.
Camera-map every offset, elbow, and pinch to confirm flexible is required (or rigid would do).
Match diameter (round or oval) and alloy to the appliance and fuel; decide on insulation.
Feed from above through the bends, insulate, and lock positive top-plate and collar connectors.
Draft/smoke check + UL-1777 documentation for your records and warranty.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Snakes past offsets, elbows, and out-of-round tile a rigid liner can't pass
The right liner type for gas/wood inserts and high-efficiency appliance venting
UL-1777 listed flexible stainless — transferable lifetime warranty
Insulated and oval-profile options for tight, crooked, or solid-fuel flues
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The NFPA recommends an annual chimney inspection (Level 1), with sweeping done when buildup reaches 1/8" of creosote. For active wood-burning fireplaces, that's typically once per heating season.
Our chimney inspectors hold current CSIA (Chimney Safety Institute of America) certifications, verifiable via the CSIA member directory at csia.org. We also have NFI specialists for fireplace installations.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, animal trapped in flue, post-fire damage, and storm damage. Same-day in most cases.
Always. We provide a written quote before any work begins, with photos of the issues we found. Final pricing depends on chimney condition and any additional work identified during inspection.
Prime Program is our annual maintenance program at $19.99/month ($240/year). Includes: annual Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency response priority. Cancel anytime, no contract.