Chimney Liner
Is Your Chimney Liner Worn or Damaged? Expert install + repairs.
Learn moreDiagnose and fix downdraft / negative-pressure issues causing smoke to spill into the room. Solutions include extension caps, smoke guards, top-sealing dampers, or fresh-air kits.
Prices shown are starting estimates and may change with the condition, access, and scope we find on site. Only a written quote from an on-site visit is a price we commit to.
A modern home can be too tight for its own fireplace. When exhaust fans, the dryer, and the HVAC pull a sealed house negative, the fireplace and other combustion appliances can't get the air they need — so they draft poorly, spill smoke, or backdraft combustion gases into the living space. Prime Chimney Experts diagnose and correct these combustion-air and makeup-air problems at the level of the whole house, not just the firebox, with the measurement discipline that finds the real cause. Premium here is an engineered fix for an invisible, sometimes dangerous, problem.
The symptom looks like a chimney problem but usually isn't. A fireplace that smokes only when the kitchen hood is running, a flue that drafts fine on a calm day but spills when the house is buttoned up, a basement appliance that backdrafts in winter — these are makeup-air problems. The house is depressurized below what the flue can overcome, and air (and combustion gas) flows the wrong way. Diagnosing it requires putting the house into worst-case depressurization — closing doors, running every exhaust device — and measuring whether the combustion appliance zone (CAZ) still drafts or spills. Without that test, you're guessing, and guessing about backdrafting combustion gas is dangerous.
The correction matches the finding. If the fireplace itself is starved, we run a dedicated outside-combustion-air (OCA) intake to the firebox so it draws makeup air from outdoors instead of the room — designed in, not bolted on. If the whole house is the problem, we add a passive makeup-air opening or, where exhaust loads are heavy, a motorized makeup-air damper interlocked to the range hood or dryer so the house can't depressurize the combustion zone when those run. Where return-duct leakage is depressurizing a zone, we seal it. The right fix is the one that addresses how your specific house loses its balance.
A particularly common version is the orphaned water heater. When a high-efficiency furnace is installed and switches to sidewall PVC venting, it often leaves a lone water heater venting into an oversized common flue it can no longer keep warm — so that flue stops drafting and the water heater spills CO. We re-line and resize the flue to the single appliance so it drafts safely. This is a CAZ failure hiding as a venting problem, and it's exactly the kind of cause-level diagnosis a premium brand catches.
The verification standard is the same as our CO work: after the correction, we re-run the worst-case depressurization test to confirm the CAZ now drafts and doesn't spill, and document the result. A makeup-air fix that isn't re-tested under worst-case conditions is unverified — and when the failure mode is combustion-gas spillage, unverified is not acceptable. The measured before-and-after is the deliverable.
PCE performs combustion-air and CAZ correction across the continental US and the four Texas metros to one instrument-based standard. Home tightness, climate, and exhaust loads vary widely; the diagnostic and verification discipline is constant. We document the testing so the result is verifiable for you and your insurer.
This work protects health and makes the fireplace actually usable — no more smoke when the hood runs, no winter backdraft, no orphaned appliance spilling CO. If your fireplace or appliances draft inconsistently or you've had unexplained spillage, it's likely a makeup-air problem worth measuring.
At Prime Chimney Experts, a downdraft repair is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the downdraft repair is built on.
Chimney inspectionA downdraft repair isn't a matter of opinion — it's held to published national standards. Prime Chimney builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
A flue too short to clear the roofline drafts poorly. Termination must be ≥3 ft above the roof penetration and ≥2 ft above anything within 10 ft — a short flue is fixed with a height extension, not just a cap.
Where downdraft causes a gas appliance to spill, the vent is re-sized to the NFPA 54 Category I tables — most often by downsizing an oversized common flue so the orphaned appliance can keep it warm and draft.
An oversized or undersized flue is a draft cause in its own right; correct sizing follows the NFPA 211 venting tables for the appliance and chimney height.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Prime Chimney verifies them with your local authority having jurisdiction on every job.
Test draft, flue height, sizing, and house pressure.
Match the fix to the cause — cap, top, or sizing.
Fit the corrective solution.
Confirm proper draft with a live test.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Diagnose the actual cause, not a generic 'cap it'
Solutions from caps to draft-inducing tops
Address house-pressure and sizing factors
Verified draft after the fix
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The NFPA recommends an annual chimney inspection (Level 1), with sweeping done when buildup reaches 1/8" of creosote. For active wood-burning fireplaces, that's typically once per heating season.
Our chimney inspectors hold current CSIA (Chimney Safety Institute of America) certifications, verifiable via the CSIA member directory at csia.org. We also have NFI specialists for fireplace installations.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, animal trapped in flue, post-fire damage, and storm damage. Same-day in most cases.
Always. We provide a written quote before any work begins, with photos of the issues we found. Final pricing depends on chimney condition and any additional work identified during inspection.
Prime Program is our annual maintenance program at $19.99/month ($240/year). Includes: annual Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency response priority. Cancel anytime, no contract.
Last reviewed:
Other services in the Repair category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line