Chimney Cap
Is Your Chimney Missing a Cap? Expert install + maintenance.
Learn moreInstall or replace the spark arrestor mesh on your chimney cap. Code-required in wildfire zones; 3/8"–1/2" mesh openings sized per NFPA 211. Often paired with a new stainless cap.
Prices shown are starting estimates and may change with the condition, access, and scope we find on site. Only a written quote from an on-site visit is a price we commit to.
A spark arrestor does one fire-safety job: it catches the live embers a wood fire sends up the flue before they can land burning on your roof or in dry brush. Hot, lightweight embers ride the draft all the way to the top, and over a combustible roof or in a wildfire-prone area an escaping ember is a roof-fire or wildland-fire ignition source. Prime Chimney Experts installs and retrofits arrestor screens sized and built to contain those embers reliably. How this differs from our chimney-cap service: a cap is the weather-and-animal lid that keeps rain and wildlife out; a spark arrestor is the ember screen that keeps fire in. The two are often combined in one fitting, but their jobs run in opposite directions — the cap protects the flue from the outside, the arrestor protects the outside from the flue.
The mesh sizing is the heart of this job, and it's a genuine balancing act the cap never has to make. The screen openings have to be small enough to stop an ember — no larger than 1/2 inch under NFPA 211 — yet open enough not to clog with soot and choke the draft, which is why code also sets a 3/8-inch minimum. Too fine a screen sooted shut, and the appliance smokes back into the room; too coarse, and embers sail right through. We size the mesh to the code range and to the way the appliance actually burns, and we build the screen in stainless so it doesn't rust thin and fail open — a corroded arrestor is a screen with holes in it, no longer arresting anything.
Much of this work is a retrofit, not a new top. Many chimneys already carry a perfectly good weather cap but no ember screen, or an old arrestor that has rusted through, torn, or sooted solid — so we add or replace the mesh on the existing fitting rather than reinventing the whole top. Where a chimney has no top hardware at all, we install an arrestor that's integrated into a cap so the homeowner gets ember containment and weather protection in one trip; but the arrestor function — the code-sized screen — is what this service is specifically about, and we'll fit one to a cap you already own. How this differs from the cap page: there the question is sealing out rain and animals; here it's screening in sparks to a verified mesh size.
Where this service earns its keep is the wildland-urban interface and any home near trees or dry brush — the places where a single escaped ember is a real wildfire risk and a local burn code or insurer often makes a compliant arrestor mandatory. We confirm the local requirement, which can be stricter than the NFPA baseline, and document the installed mesh size so the screen is provably code-compliant for an inspection or insurance file. The same containment standard governs the work across our national network, with particular weight in fire-prone markets: a confirmed mesh size, a stainless screen that won't rust open, and a fitting that stays put — so the embers your fire throws stay inside the flue where they belong.
At Prime Chimney Experts, a spark arrestor installation is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the spark arrestor installation is built on.
Chimney inspectionA spark arrestor installation isn't a matter of opinion — it's held to published national standards. Prime Chimney builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
The arrestor screen must have openings no larger than 1/2 inch to catch escaping embers, and NFPA 211 also sets a 3/8-inch minimum so the mesh doesn't soot shut and choke the draft. The size range is what makes an arrestor different from a plain cap collar — it is engineered to stop sparks while still venting.
A spark arrestor is required where the chimney serves a solid-fuel appliance and terminates over a combustible roof — the case where an escaping ember can ignite the roofing. This is a fire-containment requirement, not a weather one.
Homes in a wildland-urban interface or designated fire-hazard zone are often held to a local arrestor standard tighter than the NFPA baseline; the stricter local mesh and material requirement governs, and we install and document to it.
The screen is built in stainless so it doesn't rust thin and fail open — a rusted-out mesh has gaps an ember passes straight through and no longer arrests sparks, regardless of how the cap around it looks.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Prime Chimney verifies them with your local authority having jurisdiction on every job.
Check for an existing cap/screen and the local wildfire-code mesh requirement.
Select stainless mesh within the 3/8"–1/2" range — stops embers without choking draft.
Add the screen to the existing cap or install an integrated arrestor-cap, mounted to stay put.
Verify the installed mesh size and photo-document it for code or insurance.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Mesh sized to the NFPA 211 ember-containment range — fine enough to stop sparks, open enough to draft
Retrofit onto your existing cap — we add the ember screen, not a whole new top
Stainless screen that won't rust thin and fail open over a combustible roof
Installed mesh size documented for wildfire-code and insurance files
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The NFPA recommends an annual chimney inspection (Level 1), with sweeping done when buildup reaches 1/8" of creosote. For active wood-burning fireplaces, that's typically once per heating season.
Our chimney inspectors hold current CSIA (Chimney Safety Institute of America) certifications, verifiable via the CSIA member directory at csia.org. We also have NFI specialists for fireplace installations.
Yes — emergency response is available 24/7 (subject to crew availability) for active water leaks, animal trapped in flue, post-fire damage, and storm damage. Same-day in most cases.
Always. We provide a written quote before any work begins, with photos of the issues we found. Final pricing depends on chimney condition and any additional work identified during inspection.
Prime Program is our annual maintenance program at $19.99/month ($240/year). Includes: annual Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency response priority. Cancel anytime, no contract.
Last reviewed:
Other services in the Installation category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line